For Plants & Industries · ISO Certified

Roof Mounted Anti Smog Gun ECS-100

Fixed-type permanent dust suppression cannon with a 75–100 metre throw, 27,000 sqm coverage and 32 SS-304 nozzles — engineered for plants, warehouses, ports and cement units.

Fixed Industrial Series

Permanent Plant-Grade Dust Suppression

The ECS-100 is the most powerful unit in the Empower range — designed for permanent installation on plant rooftops, mast towers or perimeter poles. A 20 HP industrial fan combined with a 5 HP high-pressure multi-stage pump delivers a tightly atomised fog throw of 75 to 100 metres, blanketing up to 27,000 sqm around the installation point. The system runs continuously on plant water and 440 V three-phase supply, and is fully PLC-controlled with auto-swing, timer and auto-sensor logic for unattended operation.

100m

Throw Distance

27k m²

Coverage Area

32

SS-304 Nozzles

  • Fixed permanent installation on roof, mast or pole structure
  • 20 HP fan motor (Crompton / Havells) at 2800 RPM
  • 5 HP high-pressure piston / multi-stage pump (CRI / LUBI / Kirloskar)
  • 32 stainless steel (SS-304) nozzles with SS-304 nozzle ring
  • IP-65 PLC control panel — emergency stop, timer, phase preventer, DRP
  • 270° horizontal auto-swing & 60° upward rotation
  • 6 ft length × 4 ft width × 8 ft height cannon body
  • Heavy 100×50 mm channel structure with conical front casing
ECS-100 Roof Mounted Anti Smog Gun fixed type permanent dust suppression cannon
Model ECS-100 · Fixed Type
Built for 24×7

Engineering Highlights

PLC Smart Controls

IP-65 panel with PLC, emergency button, mechanical timer, auto sensor, phase preventer and DRP — all electricals are Schneider make.

270° Auto-Swing

Motorised horizontal swing covers full perimeter with programmable arc; 60° vertical tilt adjusted mechanically.

Fine Atomisation

Droplet sizes from 5–20 microns up to 150–200 microns through 32 SS-304 nozzles for maximum PM capture.

High-Pressure Pump

5 HP high-pressure piston / multi-stage pump — CRI, LUBI or Kirloskar make — with 100 micron water filter.

Heavy MS Structure

100×50 mm channel structure, 3 mm MS body, conical front casing and heavy-duty back safety guard.

Industrial Power

20 HP fan motor at 2800 RPM, 440 V three-phase supply, designed for continuous operation throughout the year.

Detailed Specs

ECS-100 Specifications

Complete factory parameters for the Roof Mounted Anti Smog Gun fixed-type system.

Parameter Specification
Model Number ECS-100-A
Throw Distance 75 – 100 metres
Water Droplet Size 5–20 / 150–200 microns
Coverage Area 27,000 sqm (minimum)
Mounting Type Fixed (Roof / Mast / Pole)
Operation Manual & Automatic Swing
Fan Motor 20 HP · 2800 RPM (Crompton / Havells)
Water Pump 5 HP High-Pressure Piston / Multi-Stage (CRI / LUBI / Kirloskar)
Number of Nozzles 32 (SS-304)
Nozzle Ring SS-304
Water Filter 100 micron
Upward Rotation 60° (Mechanical)
Horizontal Rotation 270° (Auto-Swing)
Water Consumption 55 LPM
Timer Mechanical Timer
Body Material MS (3 mm minimum thickness)
Cannon Length 6 feet
Cannon Width 4 feet
Cannon Height 8 feet
Control Panel IP-65 · Schneider PLC, Emergency Button, Timer, Auto Sensor, Phase Preventer, DRP
Structure Heavy 100 × 50 mm channel
Back Safety Guard Heavy Duty
Front Cone Arrangement Conical Casing
Cannon Front Parts MS
Power Supply 440 V (3 Phase)
Warranty 12 months against manufacturing defect
Installation Included
Where It Fits

Plant & Industry Applications

Fixed roof mounted units are deployed at sites that need permanent, plant-wide perimeter dust suppression.

Cement Plants

Clinker yards, packing houses and crusher zones.

Steel & Power Plants

Coal handling, fly-ash silos, slag yards and ESP outlets.

Warehouses & Yards

Permanent perimeter coverage for open material storage.

Ports & Berths

Captive ports for coal, iron ore and aggregate cargo.

Mines & Quarries

Fixed installation at primary crushing & screening plants.

Smart-City Hubs

CPCB-mandated installation at construction-cluster zones.

FAQ

ECS-100 Common Questions

Is installation included with the ECS-100?

Yes. Installation and basic commissioning are included in our standard quotation. Buyer is responsible for civil foundation, lifting / crane, electrical cable run from MCC to control panel, and water inlet line up to the unit.

Can multiple ECS-100 units be linked together?

Yes. Multiple units can be linked through a single master PLC for synchronised auto-swing and timer programs across the plant — ideal for large cement plants, steel works and ports.

What is the typical electrical and water connection?

440 V three-phase 50 Hz electrical supply with a dedicated MCB; water supply at 3–5 bar through a 100-micron in-line filter. Tank or sump-fed water lines are both supported.

Does the ECS-100 work with surfactants?

Yes. The pump and SS-304 nozzles are compatible with chemical surfactant dosing for enhanced PM2.5 / PM10 capture, particularly useful in coal and fly-ash dust environments.

What is the lead time for delivery?

10–15 working days from confirmed PO and advance payment, subject to standard configuration. Custom dimensions or non-standard mounting structures may take longer.
Explore Range

Related Machinery

Ready to Suppress Dust?

Talk to our engineers about your site. We deliver in 7 days.

Call Now